Plastic Bottle WVTR: How to Compare Moisture Barrier Test Results
Compare plastic bottle WVTR using the same test method, temperature, humidity and reporting units. Ask for results on the exact bottle, cap and liner you would buy. When those details differ, the lower number alone gives you too little information to choose between quotations.

Water vapor transmission rate (WVTR), also called moisture vapor transmission rate (MVTR) in packaging reports, describes how quickly water vapor passes through the tested material or package under stated conditions. For a closed bottle, a result in mg per bottle per day describes water mass per unit of time. Your quality team can use that result to screen candidates for a moisture-sensitive tablet or capsule and decide which assembly to evaluate with the product.
Which bottle had the lower measured WVTR?
In a 2025 GERPAC conference report, Sury and Marçon compared two multidose bottle models with LDPE snap-on caps. The HDPE assembly averaged 3.525 mg per bottle per day and the PET assembly averaged 17.85 mg per bottle per day. The researchers tested 12 bottles of each model over 35 days at chamber targets of 40 °C and 75% relative humidity (RH). They estimated each rate from the change in mass over time. Sury and Marçon’s conference report.

| Bottle body | Closure | Mean ± SD (mg per bottle per day) |
|---|---|---|
| HDPE | LDPE snap-on cap | 3.525 ± 0.614 |
| PET | LDPE snap-on cap | 17.85 ± 0.235 |
The PET model’s mean was about 5.1 times the HDPE model’s mean in that test. Use the comparison to shortlist designs for evaluation. The public report identifies two finished models and does not specify whether wall thickness and geometry were matched. Its ratio therefore describes those assemblies, with their own designs and closures. For a new order, get the corresponding report for the proposed package.
Why can two HDPE bottle reports give different numbers?
Start with the chamber settings and the bottle format. Chen and Li measured eight HDPE bottle sizes using capped, induction-sealed bottles containing dry desiccant. They calculated WVTR from the steady portion of the mass-gain curve. Three formats from their study are shown below, with ten bottles per reported format and condition. Chen and Li, International Journal of Pharmaceutics (2008) · Table 3 in the original paper.

| Format | 25 °C / 60% RH | 30 °C / 65% RH | 40 °C / 75% RH |
|---|---|---|---|
| 1 oz | 0.21 ± 0.01 | 0.34 ± 0.01 | 0.92 ± 0.01 |
| 3 oz | 0.36 ± 0.01 | 0.53 ± 0.02 | 1.28 ± 0.02 |
| 5 oz | 0.68 ± 0.02 | 1.12 ± 0.03 | 2.82 ± 0.05 |
The same 5 oz format averaged 0.68 mg per bottle per day at 25 °C / 60% RH and 2.82 at 40 °C / 75% RH. The second rate was about 4.1 times the first. Both temperature and humidity changed between those settings. If two supplier reports have a gap of that size, check the conditions before attributing it to the bottle design.
The three formats also have different rates at each shared setting. Their surface area and wall thickness can differ, so record the exact size and drawing revision. A change in bottle volume for the same tablet count is a good reason to ask whether the existing barrier report still covers the package you are considering. Keep the bottle, closure and liner together when approving the sample. Guide to matching bottle necks, caps and liners.
Check what the WVTR unit is measuring
A resin film result expressed in g/m²/day is a rate per area for the specimen in that test. A result expressed in mg/bottle/day is a rate for the tested bottle assembly. You can convert grams to milligrams, but you still need the same basis of measurement to compare the figures. Film thickness, bottle geometry and the closure matter when moving from a flat specimen to an assembled bottle.
If a report normalizes the rate by volume, ask how the test method defines that volume. An order’s nominal fill is a separate specification, and the report needs to state the volume used for its calculation. Guide to nominal and brimful capacity.
WVTR is one input to product stability work. The amount of moisture a tablet takes up depends on the product and the internal humidity history. The filled pack, any desiccant, and repeated opening in use can affect that history. Ask your quality team to establish the package performance target and assess the selected assembly with the actual product. USP general chapter <1671> on moisture vapor transmission and solid oral dosage forms.
What to request in a bottle WVTR report
Send suppliers the same brief. Ask for the test report and a sample list that identifies the components in the quotation. If the closest report covers a different size, closure or liner, record the difference and decide with your quality team what needs testing under the agreed method.
| Field | What to ask for | Why it matters |
|---|---|---|
| Bottle | Part number, drawing revision, material, size and wall specifications. | Identifies the tested design and helps track substitutions. |
| Closure | Cap and liner part numbers, seal type, and assembly or sealing settings where applicable. | Matches the tested configuration to the quoted one. |
| Test protocol | Method and edition, temperature, RH, test duration and preparation of the samples. | Gives both suppliers the same conditions for comparison. |
| Reported result | Units, sample count, individual values or variability, and the calculation basis. | Shows the spread of results and how the rate was derived. |
| Project acceptance | Agreed requirement, sample configuration and how the finished pack will be evaluated. | Connects the report to the product’s protection needs. |

A liquid leak test and a moisture transmission test address different questions. If visible liquid leakage matters for your project, specify the appropriate integrity check as well. FDA’s container closure guidance discusses moisture permeation and other protection tests for assembled systems. FDA guidance on container closure systems.
For a quotation from Zhuojing Package, share the bottle size or tablet count, cap and liner configuration, and any WVTR method or target your team has set. Ask which sample assembly corresponds to the quote and which measurements are available for it. Contact Zhuojing Package.
How the charts were made
The first chart uses the reported means and standard deviations from Sury and Marçon. The second plots three selected rows from Chen and Li’s Table 3. The studies used different assemblies and protocols, so each figure keeps its own dataset. The ratios in the text are calculated from the published means and rounded to one decimal place. The third figure is a buyer workflow based on the report fields discussed here.
FAQ
What does a lower bottle WVTR mean?
Under comparable test conditions it means less water vapor passed through the tested assembly per unit of time. Your quality team determines whether that rate provides enough protection for the intended product and storage conditions.
Can I compare an HDPE result at 25 °C with a PET result at 40 °C?
Ask for a comparison at the same temperature and relative humidity using the same test method and units. The two reports can help you identify what to test, but their numerical gap includes the difference in chamber conditions.
Does changing the cap or liner affect which report I should use?
Yes. Confirm that the report covers the proposed bottle, cap, liner and seal configuration. Have your quality team review any change that falls outside the tested assembly.
Does a WVTR result establish shelf life?
Shelf life depends on the filled product’s stability in its intended package and storage conditions. WVTR characterizes a moisture transmission rate and helps your team choose an assembly for that evaluation.
Can I use the study’s silica gel amount to specify a desiccant for my order?
The silica gel served as part of the researchers’ measurement method. Specify a commercial desiccant using the product’s moisture sensitivity, package configuration and in-use conditions, with suitable evaluation of the filled pack.